Electric Detonators

Disable Electric Detonator

Non-failure Electric Detonator

Detonating Cord Adaptor

Part Number, Shell Length, and Temperature Rate
Disable Detonator *Non-failure DetonatorShell Length (mm/in)Temperature Rate (°F/°C)
QH-140S-A-RDXQH-140-A-RDX36.0/1.42284/140, 2hrs
QH-140S-A-HMXQH-140-A-HMX36.0/1.42356/180, 2hrs
QH-140S-B-RDXQH-140-B-RDX36.0/1.42284/140, 2hrs
QH-140S-B-HMXQH-140-B-HMX36.0/1.42356/180, 2hrs
QH-140S-C-RDXQH-140-C-RDX36.0/1.42284/140, 2hrs
QH-140S-C-HMXQH-140-C-HMX36.0/1.42356/180, 2hrs
QH-140S-D-RDXQH-140-D-RDX36.0/1.42284/140, 2hrs
QH-140S-D-HMXQH-140-D-HMX36.0/1.42356/180, 2hrs
* The “S” denotes the electric detonator is fluid disabled. Fluid disabled detonators are installed with two symmetrical failure holes (D: 2 mm)
Specifications
Base Charge0.45/6.94 (gram/grain) RDX or HMX
Initiating Charge 0.18/2.78 (gram/grain)
Diameter7.1/0.28 (mm/in)
Wire (0.6m/Cu 22 gauge)∅1.1±0.1 (mm), Red and Black, Teflon
Resistance54-57 (Ω)
Max. No-fire Current0.2 (A)/5 (min)
Firing Current0.8 (A)
Electric Fuse-head StructureRigid, 0.03/0.46 (gram/grain)
Electrostatic Sensitivity781mJ
Failure FunctionImmersed into the water with the pressure of 0.65MPa for 30min, base charge of detonator will fail.